Check 4 of 5 · Heavy metals
We measure lead, arsenic, cadmium and mercury in every batch by ICP-MS, and each result goes on your batch report.
The blind spot
Purity is measured by HPLC. It separates the peptide from closely related compounds and reports the peptide's share of the total. Metals sit at parts per million, so a different instrument measures them.
A batch can pick up lead from a reagent, a catalyst, or a steel surface it touched during manufacturing. The metals test measures it.
Your batch report gives a measured result for each metal.
Every batch
Added per product
More elements join the screen when they could come from how the product is made:
What we screen
Lead, arsenic, cadmium and mercury are the four elements in the highest-concern class of ICH Q3D, the guideline drug makers use for elemental impurities. We test for all four in every batch.
The rest depends on how each product is made. Before we approve a supplier or a process, we run a broad elemental screen. Any element that could come from that product's synthesis, catalysts, reagents, water, equipment or packaging is added to its every-batch test.
We repeat that assessment whenever a supplier, process, piece of equipment or packaging changes. We test the finished product as well as the raw peptide, because contamination can enter after synthesis.
How limits are set
A limit means little if it is chosen after the result comes in. We set each product's limits in advance, using ICH Q3D as the benchmark. It sets a permitted exposure for each element.
We allow any one product no more than 10% of that limit for each element. Below that release limit sits a stricter internal alert limit. A batch above the release limit fails. A result above the alert limit starts an investigation, even when the batch passes.
The lab's method must also measure well below our limit. A method that measures well below the limit shows how far below it each batch sits.
Inside our 10%
The most of any element's framework limit we allow one product to use
The margin is the point.
Every measurement carries some uncertainty, and every batch differs a little from the last. Leaving 90% of the limit unused keeps those differences far from it.
Trending
Each result is a number, so we plot it across batches. Steady, low results mean the process is under control. Results that creep up mean something upstream has changed, such as a new reagent lot or a worn part.
A rising trend starts an investigation at the alert limit, long before a batch could fail. A batch that does fail is destroyed.
The number the lab measured, so you can check it against the limit.
The smallest amount the method can report reliably for that element.
The number this product had to stay under, set before testing.
The laboratory that ran the test and the method it used.
Look for each metal by name, with its result.
A number gives you something to compare against the limit.
Ask which framework it came from and whether it was fixed before testing.
ISO/IEC 17025 accreditation covers specific methods. Ask whether this one is listed.
Your batch
Enter the batch number from your label to see the results for the vial in your hands.
Buy One, Get One FREE! The lowest-priced item in each pair is on us. Get up to 5 FREE items per order! Offer valid until November 30, 2026